Canon GC-201 Scanner User Manual


 
CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
127
9.4. Writing Parameters into ROM
All parameters are written in the controller ROM. At Start up, the parameters are automatically read
and set in the controller.
If parameters are modified, they should be written into ROM for start up with the same settings at the
next power-on. Write modified parameters into ROM as follows:
Control Software
Select the All Parameter tab.
Select an axis for parameter settings.
The current parameter values are displayed.
Press the Save to EEPROM button.
Input password “Canon”
“Saving to EEPROM” is displayed.
Note: Some parameter settings may disable normal start up next time.
If this problem occurs, change the start up mode for no automatic homing to the origin and
check the set values. (See 6.1, “Setting Controller Start Up Mode.”)