Dell R805 Server User Manual


 
160 Troubleshooting Your System
b
Open the system. See "Opening and Closing the System" on page 70.
c
Reinstall one of the expansion cards.
d
Close the system. See "Opening and Closing the System" on page 70.
e
Run the appropriate diagnostic test.
If the tests fail, see "Getting Help" on page 175.
Troubleshooting the Microprocessors
Problem
Error message indicates a processor problem.
Front-panel status LCD indicates a problem with the processors or system
board.
A heat sink is not installed for each processor.
Action
CAUTION: Only trained service technicians are authorized to remove the system
cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer and protecting against
electrostatic discharge.
1
Run the appropriate online diagnostics test. See "Using Server
Administrator Diagnostics" on page 161.
2
Turn off the system and attached peripherals, and disconnect the system
from the electrical outlet.
3
Open the system. See "Opening and Closing the System" on page 70.
4
Inspect each processor and heat sink and ensure that they are properly
installed.
If you need to make adjustments, see "Installing a Processor" on page 123.
5
Close the system. See "Opening and Closing the System" on page 70.
6
Reconnect the system to the electrical outlet, and turn on the system and
attached peripherals.
7
Run the appropriate online diagnostic test.
If the tests fail or the problem persists,
see
"Getting Help" on page 175.