Dell R805 Server User Manual


 
26 About Your System
E1414 CPU #
Thermtrip
Specified microprocessor is
out of acceptable
temperature range and has
halted operation.
See "Troubleshooting
System Cooling
Problems" on page 149. If
the problem persists,
ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 160.
NOTE: The LCD continues
to display this message
until the system’s power
cord is disconnected and
reconnected to the AC
power source, or the SEL is
cleared using either Server
Assistant or the BMC
Management Utility. See
the Dell OpenManage™
Baseboard Management
Controller User’s Guide for
information about these
utilities.
E1418 CPU #
Presence
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
See "Troubleshooting the
Microprocessors" on
page 160.
E141C CPU Mismatch Processors are in a
configuration unsupported
by Dell.
Ensure that your
processors match and
conform to the type
described in the
Microprocessor Technical
Specifications outlined in
your system’s Getting
Started Guide.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions