Dell R805 Server User Manual


 
About Your System 41
PCIe Training
Error: Slot
n
Faulty or improperly installed
PCIe card in the specified
slot.
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" on
page 91. If the problem
persists, see "Getting Help"
on page 175.
Plug & Play
Configuration
Error
Error encountered in
initializing PCIe device;
faulty system board.
Install the NVRAM_CLR
jumper and reboot the
system. See Figure 6-1 for
jumper location. If the
problem persists, see
"Troubleshooting Expansion
Cards" on page 158.
Read fault
Requested sector
not found
The operating system cannot
read from the hard drive or
USB device, the system could
not find a particular sector on
the disk, or the requested
sector is defective.
Replace the USB medium or
device. Ensure that the USB
or hard drive cables are
properly connected. See
"Troubleshooting a USB
Device" on page 143, or
"Troubleshooting a Hard
Drive" on page 155 for the
appropriate drive(s) installed
in your system.
Remote Access
Controller cable
error or
incorrect card in
the RAC slot.
RAC cables not connected,
or RAC card installed in
wrong expansion slot.
Check that the RAC cables
are connected, and that the
RAC card is installed in the
correct expansion slot. See
"Installing a RAC Card" on
page 106.
Remote
configuration
update attempt
failed
System unable to process
Remote Configuration
request
Retry Remote Configuration.
Table 1-7. System Messages (continued)
Message Causes Corrective Actions