About Your System 31
E1B01 USB#
Overcurrent
Device plugged in the
specified USB port caused
an overcurrent condition.
Reseat the device cable. If
the problem persists,
replace or remove the
device.
E2010 No Memory No memory is installed in
the system.
Install memory. See
"Installing Memory
Modules" on page 117.
E2011 Mem Config
Err
Memory detected, but is not
configurable. Error detected
during memory
configuration.
See "Troubleshooting
System Memory" on
page 150.
E2012 Unusable
Memory
Memory is configured, but
not usable. Memory
subsystem failure.
See "Troubleshooting
System Memory" on
page 150.
E2013 Shadow BIOS
Fail
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 150.
E2014 CMOS Fail CMOS failure. CMOS RAM
not functioning properly.
See "Getting Help" on
page 175.
E2015 DMA
Controller
DMA controller failure. See "Getting Help" on
page 175.
E2016 Int
Controller
Interrupt controller failure. See "Getting Help" on
page 175.
E2017 Timer Fail Timer refresh failure. See "Getting Help" on
page 175.
E2018 Prog Timer Programmable interval
timer error.
See "Getting Help" on
page 175.
E2019 Parity Error Parity error. See "Getting Help" on
page 175.
E201A SIO Err SIO failure. See "Getting Help" on
page 175.
E201B Kybd
Controller
Keyboard controller failure. See "Getting Help" on
page 175.
Table 1-6. LCD Status Messages (continued)
Code Text Causes Corrective Actions