Emerson CC1000DM Network Card User Manual


 
SETUP
Operational Checks
2-10 CC1000dm User’s Manual 10004281-02
2
Power Requirements
Be sure your power supply is sufficient for the board. The combined power (3.3 volts
and 5 volts) for a CC1000dm is 27 watts.
Table 2-5 lists the specific power requirements
for the CC1000dm. Please contact Artesyn Technical Support at 1http://www.arte-
syncp.com/support on the internet or send E-mail to support@artesyncp.com if you
have specific questions regarding the board’s power requirements.
Environmental Considerations
As with any printed circuit board, be sure that air flow to the board is adequate. Chassis
constraints and other factors greatly affect the air flow rate. The environmental require-
ments are as follows:.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATIONAL CHECKS
All products are tested before they are shipped from the factory. When you receive your
CC1000dm, follow these steps to assure yourself that the system is operational:
1 Visually inspect the board for components that could have loosened during shipment.
2 Verify that the front panel is secure.
3 By default, the CC1000dm carrier card is configured to support 3.3 V I/O operation on the
secondary bus. Please be sure to select the appropriate voltage for your application.
Voltage: Range:
Typical Current
(amps): Usage:
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
+3.3 V +5/-3% 1.0 Board logic
+5 V +5/-3% 0.4 Board logic
+12 V ±5% 0.5 PMC slot power
–12 V ±5% 0.5 PMC slot power
VIO ±5% 0.75 PCI signaling for board logic
Voltage: Usage:
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
Operating Temperature 0 to +55
O
Centigrade, ambient (at board)
Relative Humidity Not to exceed 95% (non-condensing)
Storage Temperature -40 to +85
O
Centigrade, ambient
Shock and Vibration NEBS Level 3 compliant
Ta b l e 2 - 5 :
Power Requirements
Ta b l e 2 - 6 :