Extreme Networks 8800 Series Switch User Manual


 
Technical Specifications
BlackDiamond 8800 Series Switches Hardware Installation Guide
172
Power Supplies for BlackDiamond 8800 Series
Switches
Table 21: Specifications for the AC SSI PS Model #60020/PS2336 (700/1200 W AC PSU)
Compatible with the BlackDiamond 8806 and 8810 switches
Typical configuration 3 power supplies
Full configuration 6 power supplies
Input Nominal input: 100 to 240 V~, 60/50 Hz, 10 A max
AC voltage input range: 90 to 264 V~
Maximum input amperages:
7 A @ 200 V~ (high-line)
10 A @ 90 V~ (low-line)
AC line frequency: 47 to 63 Hz
PS input socket: IEC 320 C14
Minimum wire size: 16 AWG (1.31mm
2
) copper stranded
Output DC output: 48 V , 24 A/12 V , 4 A (high-line)
48 V , 13.5 A/12 V , 4 A (low-line)
DC output power (W): 700 to 1200 W
Power supply cord selection Refer to “Selecting Power Supply Cords” on page 158.
AC power supply input socket IEC 320 C14
Minimum wire size 16 AWG (1.0mm
2
) copper stranded
(pre-approved cord set for county of use)
Operating conditions Operating temperature: 0° C to 40° C
Storage temperature: –40° C to 70° C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s
2
(3 g)
Table 22: Specifications for the AC PS Model #41050 (600/900 W AC PSU)
Compatible with the BlackDiamond 8806 switch
Typical configuration 3 power supplies
Full configuration 6 power supplies
Input Nominal input voltage: 100 to 240 V~, 60/50 Hz, 8 A max
Voltage input range/frequency range: 90 to 264 V~
AC line frequency: 47 to 63 Hz
Maximum input amperages:
5 A @ 200 V~ (high-line)
8 A @ 90 V~ (low-line)
Input socket: IEC 320 C14
Minimum wire size: 16 AWG (1.31mm
2
) copper stranded (pre-approved cord set
for country of use)
Output DC output:
48V , 18A/12V , 4A (high line)
48V , 11.5A/12V ,4A (low line)
DC output power (W): 600 to 900 W
Power supply cord selection Refer to “Selecting Power Supply Cords” on page 158.
Operating conditions Operating temperature: 0° C to 40° C (32° F to 104° F)
Storage temperature: –40° C to 70° C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s
2