Extreme Networks 8800 Series Switch User Manual


 
BlackDiamond 8800 Series Modules
BlackDiamond 8800 Series Switches Hardware Installation Guide
24
NOTE
See the ExtremeXOS 12.1 Concepts Guide and the ExtremeXOS 12.1 Command Reference Guide for more
information about numbering conventions for the modules and ports, as well as configuration and display
information.
MSM LEDs
Table 3 describes the LED activity on the BlackDiamond 8800 series MSMs.
NOTE
The LEDs on the management Ethernet port are not labeled. On most modules, the LED on the right is the link
LED, and the one on the left is the activity LED. On the MSM-48c, the left LED indicates link status, and the right
LED indicates link activity by blinking green.
NOTE
The data port LEDs on the MSM-G8X operate the same as the port status LEDs on the G24X I/O module.
Table 3: MSM-G8X, MSM-48. and MSM-48c LEDs
LED Color Indicates
SYS/STA Green blinking Normal operation is occurring.
Amber blinking The status LED flashes amber while diagnostic tests are running on
the module. If a diagnostic test fails, the status LED becomes solid
amber. The LED resets if the diagnostics are terminated. The LED
returns to flashing amber if another diagnostic test is started.
Amber Diagnostic failure has occurred.
Off Switch is not receiving power.
MSTR/DIAG Green Module is operating as primary MSM.
Amber Module is operating as backup (secondary) MSM.
Green blinking Power-on self-test (POST) is running.
Off Normal operation for diagnostics.
ERR Amber A critical software error has been logged since power-up.
Off Normal operation is occurring.
ENV Green Environment (temperature, fan, power supply) is operating properly.
Amber Environmental failure has occurred.
Link on MSTR
Ethernet port
Green Link is up.
Off Link is down.
Activity on MSTR Amber Packet activity is occurring.