Extron electronic MPS 601 Switch User Manual


 
Connection Options
The MPS601 can be remotely connected to a host computer or other device (such as a
control system) attached to the rear panel RS-232 port or the front panel USB Config port.
The switcher can be set up and controlled using Simple Instruction Set (SIS) commands.
SIS commandsare executed using the Extron DataViewer program, found at
www.extron.com.
Remote Control Port (RS-232)
The RS-232 port connector (see figure 2,
H
on page 4) connects to a host or external
controlling device, such as a computer or control system, which can generate the proper
command codes and recognize switcher responses.
The RS-232 connector on the PC is a 9-pin D female with the following pin designations:
Pin RS-232 Function Description
1 - No connection
2 Tx Transmit data
3 Rx Receive data
4 - No connection
5 Gnd Signal ground
6,7 - No connection
8,9 - No connection
The protocol for the serial port is: 9600 baud, no parity, 8 data bits, 1 stop bit, no flow
control. Commands and responses for programming the MPS601 from a host system
connected to the RS -232 or USB port are listed later in this chapter.
Remote
Communication and
Control
This section discusses SIS programming and control of the MPS601 including:
Connection Options
Host-to-MPS Communications
Command and Response Table
51
9
5
9
6
1
6
Female Male
MPS601 • Remote Communication and Control 18