Extron electronic MPS 601 Switch User Manual


 
Command and Response Table
Using the Command and Response Table
The command and response table is shown on the following pages. Lower case characters
are acceptable in the command field only where indicated. Symbols are used throughout
the table to represent variables in the command and response fields. Symbol definitions and
an ASCII-to-hexadecimal (HEX) conversion table are shown below. Command and response
examples are shown throughout the command and response table.
Symbol definitions
]
=
CR/LF (carriage return/line feed) (hex 0D 0A).
}
=
Carriage return (no line feed, hex 0D).
|
= Pipe (vertical bar) character
=
Space character in command or response (all other spaces shown are for clarity).
W
Can be used interchangeably with the
E
character
E
=
Escape key (hex 1B)
X!
=
Inputs 0 through 6 for single input addressing (0 =de-select)
X#
=
Status
0 = off (disable), (default)
1 = on (enable)
X$
=
Video output color bit depth
0=Auto (based on EDID), (default)
1=force 8-bit
X%
=
Signal Status
0=no signal
1=signal present.
X^
=
HDCP authorized status
0=block/disable HDCP encryption.
1=Allow/Enable HDCP encryption (default).
X&
=
EDID slot number from lookup table (see User assigned EDID Mode on page16):
1-64 = factory EDIDs,
65 = Output (autodetect),
66-69 = user loaded EDID slots.
X*
= Native resolution and refresh rate from EDID.
X(
=
Firmware version, Example: 1.00
X1)
=
Firmware and build version, Example: 1.00.0001
X1$
=
Executive mode
0=unlocked/disabled (default)
1=locked/enabled
X1%
=
Audio mode
1 = Audio input A follows input 1. Audio input B follows input 2 (default).
2 = Audio input A follows inputs 1 and 2. Audio input B is disabled.
3 = Audio input A is grouped to inputs 1, 3, 5. Audio input B is grouped to inputs 2, 4, 6.
X1^
=
Auto input switching mode
0 = disabled, manual switching (default).
1 = on/enabled, priority to the highest active input.
2 = on/enabled, priority to the lowest active input.
X1&
=
AV mute mode
0=normal operation (no mute, default).
1=Enable AV mute by contact input.
22
MPS601 • Remote Communication and Control