Extron electronic MPS 601 Switch User Manual


 
MPS601 • Software Configuration and Control 40
Device Settings Page
The Device Settings page allows configuration of the input auto-switching and the tally
out LED indication. Click the Device Settings button on the Global Navigation Bar to open
the page.
Figure 32. Device Settings Page
Auto Switch panel
In the absense of active video on the selected input, input auto-switch mode automatically
switches inputs based on detected input signals.
1. Select the Enable Auto Switch check box to enable auto-input switch mode.
2. Click the radio button of the desired switch mode from the following:
Priority to the highest active input number — Automatically switches the
input to the highest numbered input with active video.
Priority to the lowest active input number — Automatically switches the
input to the lowest numbered input with active video.
Visual Indication of Mute Status panel
When an input uses the Extron “Show Me” cable or uses other Contact In / Tally Out
connections, the tally indicator can be configured to show the current state of the input.
To configure the indicator select.
Disabled — AV mute is disabled. The selection button provides input switching
only with the LED visual indicator always solid. Subsequent selection button
presses are ignored.
LED Off When Muted — When selected, a subsequent selection button press
button enables AV mute and shuts off the LED visual indicator. Another button
press disables AV mute and restores the LED to solid.
LED Blinks When Muted — When selected, a subsequent selection button press
button enables AV mute and blinks the LED visual indicator. Another button press
disables AV mute and restores the LED to solid.
LED Stays On When Muted — When selected, a subsequent selection button press
enables AV mute and the LED visual indicator remains lit solid. Another button press
disables AV mute.