Extron electronic MPS 601 Switch User Manual


 
Command ASCII Command
(host to switcher)
Response
(switcher to host)
Description
Information request
General information
I
In
X!
Aw0
Ausw
X1%
Vmt
X#
Amt
X#]
Video input (1-6), Audio input (1-
6), Autoswitch status, Video mute
status, Audio mute status.
Query model name
1I
MPS
601
]
Query part number
N
60-xxxx-xx
]
60-1337-01
Query Firmware version
Query firmware version
Q/q
x.xx
]
Displays firmware version number to
the second decimal.
Query firmware version with
build
*
Q/q
x.xx.xxxx
]
Displays firmware version and build
number to the fourth decimal.
EDID Minder
Assign EDID to specific input
E
A
X!
*
X&
EDID
}
EDIDA
X!
*
X&
]
X&
= 1 to 64
View EDID assignment
E
A
X!
EDID
}
X& ] X&
= 1 to 69
Save display EDID to user
location
E
S
X&
EDID
}
X&] X&
= 66 to 69
View/Read EDID of input in hex
format
E
R
X!
EDID
}
X2)]
Read HEX data (as text) from
currently selected EDID.
View EDID native resolution
E
N
X!
EDID
}
X*
]
Read native resolution and refresh
rate from currently selected EDID.
Example: 1920x1200@60Hz
NOTES:
X!
= Video Input 1 to 6 for single input addressing, 0=deselected.
X#
= Mute status 0= off/disabled, 1=on/enabled
X&
= EDID memory slot number From lookup table (see User assigned EDID Mode on page16):
1-64 = factory EDIDs,
65 = Output (autodetect),
66-69 = user loaded EDID slots.
Default: Video inputs 1 and 2=14
Video inputs 3 to 6=56.
X*
= Native resolution and refresh
rate from EDID
X2)
= EDID hex value EDID raw hex value: 128 or 256 Byte (text form)
27