Extron electronic SW2 DP Switch User Manual


 
SW2 DP • Remote Configuration and Control 18
18
18
Command
ASCII Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Unit Name
Set unit name
E
X&
CN
}
Ipn
X&
]
Set name
X&
for the SW2 DP unit.
X&
= Text string of up to 24
characters:
Letters (a-z), numerals (0-9), and
hyphens () are permitted.
Blanks or space characters are not
permitted.
No distinction is made between
upper and lower case.
The first character must be a letter;
the last character cannot be a
hyphen.
View unit name
E
CN
} X&
]
Show assigned unit name
X&
.
Information Requests
Request part number
N
60-1210-01
]
Show the switcher part number.
Query firmware version
Q
X^
]
Show firmware build number
X^
,
expressed to the second decimal
place.
Example:
Q
1.01
]
Query auto-input switching status
72 #
Asw
X@
]
Show On and Off status of
auto-input switching. For
X@
:
0 = disabled
1
= enabled
Reset
Reset
E
ZXXX
}
Zpx
]
Reset the switcher to default values,
retaining the current version of
rmware. EDID is reset to 1920x1080
@ 60 Hz.
Upload Firmware
Upload rmware
E
Upload
}
...go
Upl
]
Upload a new rmware version from
the computer. Upl appears after the
upload is complete.