Fujitsu DL6400Pro Printer User Manual


 
Serial Options
User’s Manual C-9
INTERFACE
INFORMATION
The serial options listed here must be set up the same way on both the
processor and the printer. By using the printer control panel, the
processor operating system, or software, you can change selectable
options.
Transmission mode: Asynchronous, full duplex, or half duplex
(selectable)
Speeds: 150, 300, 600, 1200, 2400, 4800, 9600, or
19200 baud (selectable)
Data bits: 7 or 8 bits (selectable)
Parity bit: Odd, even, mark, space, or none (selectable)
Start bit: 1 bit
Stop bit: 1 or 2 bits (selectable)
Protocol: XON/XOFF (DC1/DC3), DTR (Data
Terminal Ready), RC (Reverse Channel), or
ETX/ACK (selectable)
Buffer size: 256, 2K, 8K, 24K, 32K, 96K, or 128K bytes
(selectable)
11 RC Output Reverse Channel. This signal is used
in the RC protocol only. Spaces are
sent when the printer is ready to send
or receive data.
20 DTR Output Data Terminal Ready. Spaces are sent
when the printer is turned on and
ready.
Table C–2 Serial interface (Continued)
Pin
number
Signal Direction Description
Serial Options