Fujitsu M3000 Server User Manual


 
6-2 SPARC Enterprise M3000 Server Service Manual November 2009
Note When replacing the motherboard unit, attach connection destination labels
to each of the LAN cable and UPS cable connected to the XSCF unit before removing
these cables.
Note When mounting the motherboard unit, connect the LAN cable and UPS
cable to the XSCF unit.
Note After the replacement of the motherboard unit is completed, the system
clock must be reset. For details of the setting method, see the SPARC Enterprise
M3000/M4000/M5000/M8000/M9000 Servers XSCF User’s Guide.
Note After the replacement of the motherboard unit is completed, the versions of
the XCP and Solaris OS must be checked. For details of version number checking
and other such tasks, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000
Servers XSCF User’s Guide.
Because the XSCF unit is mounted on the motherboard unit, it cannot be replaced
singly. For details of the XSCF unit, see the Appendix B.2.4.