Fujitsu M3000 Server User Manual


 
Chapter 3 Troubleshooting 3-21
The following example shows output for the iostat command:
3.6.2 Using the prtdiag Command
The prtdiag command displays system configuration and diagnostic information.
The diagnostic information identifies any failed FRU in the system.
The prtdiag command is located in the /usr/platform/platform-name/sbin/
directory.
The prtdiag command may indicate a slot number different from that shown
elsewhere in this document. This is normal.
3.6.2.1 Options
TABLE 3-8 lists the options of the prtdiag command and how those options can help
troubleshooting.
# iostat -En
c0t0d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Model: ST3120026A Revision: 8.01 Serial No: 3JT4H4C2
Size: 120.03GB <120031641600 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0
c0t2d0 Soft Errors: 0 Hard Errors: 0 Transport Errors: 0
Vendor: LITE-ON Product: COMBO SOHC-4832K Revision: O3K1 Serial No:
Size: 0.00GB <0 bytes>
Media Error: 0 Device Not Ready: 0 No Device: 0 Recoverable: 0
Illegal Request: 0 Predictive Failure Analysis: 0
TABLE 3-8 Options for prtdiag
Option Description How it can help
No option Lists components. Shows CPU information, memory
configuration, PCIe cards installed, OBP
version, status of the mode switch, and CPU
operation mode.
-v Verbose mode. Provides the same information as no option.
Additionally, displays the detail information
of PCIe cards.