Fujitsu M3000 Server User Manual


 
4-4 SPARC Enterprise M3000 Server Service Manual November 2009
TABLE 4-3 lists the access location and applicable installation methods for each FRU.
Fan unit (FAN_A) Top Yes Yes
Yes
Chapter 13
Fan backplane (FANBP_B) Top Yes No No Chapter 14
Operator panel (OPNL) Front/top Yes No No Chapter 15
* The FRU is operated directly, without using XSCF commands.
The FRU is operated with XSCF commands.
The hard disk drive has a redundant configuration only when disk mirroring software is used.
If aharddisk driveisan unmirrored boot device,itmust bereplacedbyusing thecold replacementprocedure.However,if aboot
device can be disconnected by means of a Solaris OS function or disk mirroring software function, active replacement can also be
performed.Theprocedurefordisconnectingaharddiskdrivevariesdependingon thesoftwarebeingused. Fordetails,seetheman-
uals for the relevant software.
TABLE 4-3
FRU Access Locations and Installation Methods
FRU
Access
location Cold addition Hot addition
Active
addition
Where to find the
procedure
Motherboard unit
(MBU_A, MBU_A_2, MBU_A_3,
MBU_A_4)
TopNoNoNo
Memory (DIMM) Top Yes No No Chapter 7
PCIe card (PCIe) Top Yes No No Chapter 8
Hard disk drive (HDD) Front Yes Yes
*
* The FRU is operated directly, without using XSCF commands.
Yes
The FRU is operated with XSCF commands.
Chapter 9
Hard disk drive backplane (HDDBP) Top No No No
CD-RW/DVD-RW drive unit
(DVDU)
Front/top No No No
Power supply unit (PSU) Rear No No No
Fan unit (FAN_A) Top No No No
Fan backplane (FANBP_B) Top No No No
Operator panel (OPNL) Front/top No No No
TABLE 4-2 FRU Access Locations and Replacement Methods (Continued)
FRU
Access
location
Cold
replacement
Hot
replacement
Active
replacement
Where to find the
procedure