Fujitsu M3000 Server User Manual


 
Chapter 3 Troubleshooting 3-9
TABLE 3-4 shows typical messages generated when an error occurs. Messages are
displayed on your console and are recorded in the /var/adm/messages file.
A message in
TABLE 3-4 indicates that the fault has already been diagnosed. If there
was any corrective action that the system could take, the system has already taken it.
If your server is still running, the corrective action continues to be taken.
TABLE 3-4 Predictive Self-Healing Messages
Output displayed Description
Nov 1 16:30:20 dt88-292 EVENT-TIME:Tue Nov 1
16:30:20 PST 2005
EVENT-TIME: The time stamp of the diagnosis
Nov 1 16:30:20 dt88-292 PLATFORM:SUNW,A70,
CSN:-, HOSTNAME:dt88-292
PLATFORM: A description of the server encountering
the error
Nov 1 16:30:20 dt88-292 SOURCE:eft, REV: 1.13 SOURCE:Information on the Diagnosis Engine used to
determine the error
Nov 1 16:30:20 dt88-292 EVENT-ID:afc7e660-d609-
4b2f-86b8-ae7c6b8d50c4
EVENT-ID: The Universally Unique event ID for this
error
Nov 1 16:30:20 dt88-292 DESC:
Nov 1 16:30:20 dt88-292 A problem was detected in the
PCI Express subsystem
DESC: A basic description of the error
Nov 1 16:30:20 dt88-292 Refer to
http://sun.com/msg/SUN4-8000-0Y for more
information.
WEB SITE: Where to find specific information and
actions for this error
Nov 1 16:30:20 dt88-292 AUTO-RESPONSE:One or
more device instances may be disabled.
AUTO-RESPONSE: What, if anything, the system did
to alleviate any follow-on problems
Nov 1 16:30:20 dt88-292 IMPACT:Loss of services
provided by the device instances associated with this
fault.
IMPACT: A description of what is considered to be the
impact of the fault
Nov 1 16:30:20 dt88-292 REC-ACTION:Schedule a
repair procedure to replace the affected device.Use
Nov 1 16:30:20 dt88-292 fmdump -v -u EVENT_ID to
identify the device or contact Sun for support.
REC-ACTION: A brief description of the corrective
action the system administrator should take