14-6 SPARC Enterprise M3000 Server Service Manual • November 2009
14.3 Mounting the Fan Backplane
1. Place the fan backplane on the bottom of the chassis.
Adjust the fan backplane so that it is level and it does not catch on any cables.
2. Tighten the four screws to secure the fan backplane in position.
3. Connect the signal cable for the operator panel.
The cable is on the right side of the fan backplane.
4. Mount the signal cable connector for the motherboard unit.
The cable connector is to be mounted on the rear side of the fan backplane.
14.4 Reassembling the Server
1. Mount the fan cage.
Set the button of the fan cage at the A part in
FIGURE 14-3, and insert the fan cage
projections in the tabs (1 in
FIGURE 14-1).
2. Mount the fan units.
For details, see Section 13.3, “Mounting a Fan Unit” on page 13-5.
3. Attach the air duct to the server.
For details, see Section 5.3.3, “Attaching the Air Duct” on page 5-6.
4. Attach the top cover.
For details, see Section 5.2.2, “Attaching the Top Cover” on page 5-4.
5. If the equipment rack is supplied with a Quake-Resistant Options Kit or
stabilizer, return to its original position.
For details, see Section 5.1.2, “Sliding the Server into the Equipment Rack” on
page 5-3.
6. Power on the server.
This procedure includes the steps of reconnecting the power cord, checking the
LED status, and turning the mode switch on the operator panel to the Locked
position. For details, see Section 4.5.3.1, “Power-on by Using the XSCF
Command” on page 4-13.