Fujitsu M3000 Server User Manual


 
3-18 SPARC Enterprise M3000 Server Service Manual November 2009
3.5.5.2 fmadm repair Command
When the fmadm faulty command displays a fault, the fmadm repair command
must be executed to clear the FRU information in the domain after replacement of
the motherboard unit that has encountered the error. If the fmadm repair
command is not executed, the error message is not cleared.
If the fmadm faulty command displays a fault, clearing the FMA resource cache
on the operating system side causes no problem. Data in the cache does not need to
match the hardware fault information held by the XSCF.
3.5.5.3 fmadm config Command
The fmadm config command output displays the version number and current
status of the diagnosis engine that is being used by the server. Whether the latest
engine is being used can be determined by consulting the SunSolve web site.
# fmadm repair
STATERESOURCE / UUID
-------- --------------------------------------------------------
degraded dev:////pci@1e,600000
0ee65618-2218-4997-c0dc-b5c410ed8ec2
# fmadm config
MODULE VERSION STATUS DESCRIPTION
cpumem-diagnosis 1.6 active CPU/Memory Diagnosis
cpumem-retire 1.1 active CPU/Memory Retire Agent
disk-transport 1.0 active Disk Transport Agent
eft 1.16 active eft diagnosis engine
event-transport 2.0 active Event Transport Module
fabric-xlate 1.0 active Fabric Ereport Translater
fmd-self-diagnosis 1.0 active Fault Manager Self-Diagnosis
io-retire 1.0 active I/O Retire Agent
snmp-trapgen 1.0 active SNMP Trap Generation Agent
sysevent-transport 1.0 active SysEvent Transport Agent
syslog-msgs 1.0 active Syslog Messaging Agent
zfs-diagnosis 1.0 active ZFS Diagnosis Engine
zfs-retire 1.0 active ZFS Retire Agent