Chapter 12 Power Supply Unit Replacement 12-5
12.3 Mounting the Power Supply Unit
Caution – Do not forcibly push the power supply unit into the slot. Forcibly
pushing the component in a slot may damage the component or the server.
1. Align the top of the unit with the top of the slot.
Doing so prevents the bottom of the slot from cutting the power cord at the
bottom of the unit.
2. Set the handle so that it is perpendicular to the server, and then push the
power supply unit into the slot.
3. Insert the power supply unit until it reaches the predetermined position, and
then return the handle to its original position.
4. Secure the power cord with the cord clamp.
12.4 Reassembling the Server
■ From the XSCF Shell prompt, use the showhardconf command to verify that the
new power supply unit has been installed.
For details, see Section 4.4.2, “Verifying the Hardware Operation” on page 4-10.
XSCF> showhardconf