4-8 SPARC Enterprise M3000 Server Service Manual • November 2009
4.4.1 FRU Removal and Replacement
● Type the replacefru command from the XSCF Shell prompt.
XSCF> replacefru
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a type of FRU to be replaced.
1. FAN (Fan Unit)
2. PSU (Power Supply Unit)
----------------------------------------------------------------------
Select [1,2|c:cancel] :1
----------------------------------------------------------------------
Maintenance/Replacement Menu
Please select a FAN to be replaced.
No. FRU Status
--- --------------- ------------------
1. FAN_A#0 Normal
2. FAN_A#1 Normal
----------------------------------------------------------------------
Select [1,2|b:back] :1
You are about to replace FAN_A#0.
Do you want to continue?[r:replace|c:cancel] :r
Please confirm the Check LED is blinking.
If this is the case, please replace FAN_A#0.
After replacement has been completed, please select[f:finish] :f