GarrettCom MNS-6K-SECURE 14.1.4 Switch User Manual


 
MAGNUM 6K SWITCHES, MNS-6K USER GUIDE
229
group address, 224.0.0.1. The default value is 125 seconds. The valid range can be from 60 to 127
seconds.
set-qri interval=<value> -
Syntax The query response interval is the maximum amount of time that can
elapse between when the querier router sends a host-query message and when it receives a response from a
Syntax m is
in lower case and is shown in upper case for clarity
host. The Default value is 10 seconds. The Range can be from 2 to 270 seconds. Restrictions apply to the
maximum value because of an internal calculation that is dependent on the value of the Query Interval
ode <normal | L2> - Set the IGMP to use IGMP-L2 or normal IGMP. Note – the “L” in “L2”