GarrettCom MNS-6K-SECURE 14.1.4 Switch User Manual


 
MAGNUM 6K SWITCHES, MNS-6K USER GUIDE
The switch has three modes of operation – Operator (least privilege), Manager and
Configuration. The prompts for the switches change as the switch changes modes from
Operator to Manager to Configuration. The prompts are shown in Figure 2 below, with a
brief explanation of what the different prompts indicate.
Magnum6K> Operator Level – for running operations queries
Magnum6K# Manager Level – for setting and reviewing commands
Magnum6K## Configuration Level – for changing the switch parameter values
FIGURE 2 - Prompt indicating the switch model number as well as mode of operation – note the
commands to switch between the levels is not shown here.
The prompt can be changed by the user. See the Chapter on Miscellaneous Commands,
sub section Prompt for more details. This manual was documented on a Magnum 6K25
switch, and for clarity, the prompt shown in the manual will be
Magnum6K25
Fo
Us
r additional information on default users, user levels and more, see
er Management in this guide.
j
Logging in for the first time
For the first time, use the default user name and passwords assigned by GarrettCom for
the Magnum 6K family of switches. They are:
Username – manager Password – manager
Username – operator Password – operator
We recommend you login as manager for the first time to set up the IP address as well as
change user passwords or create new users.
Setting the IP parameters
To setup the switch, the IP address and other relevant TCP/IP parameters have to be
specified. A new GarrettCom Magnum switch looks for a DHCP or a BootP server. If a
DHCP or a BootP server is present, the switch will be assigned an IP address from those
servers. Failing to find these servers, the IP address is automatically assigned to
192.168.1.2 with a netmask of 255.255.255.0.
26