134 System Specifications
Environmental specifications
The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.
Variable Requirements
Temperature Maximum rate of change = 10° C per hour
Nonoperating -48.3° to 65.5° C(-55° to 150° F)
Operating 5° to 35° C(41° to 95° F); derated 0.5° Cforevery
1000 ft. (305 m)
Altitude 10,000 ft. max
Humidity
Nonoperating 95% relative (noncondensing) at 30° C(86° F)
Operating wet
bulb
Nottoexceed33°C(91.4° F) (with diskette drive or
hard drive)
Shock
Operating 2.0 g, 11 msec, 1/2 sine
Packaged Operational after 30-inch free fall (cosmetic damage
might occur)
AC Input Power
100-120 V∼ 100-120 V∼,6A,50/60Hz
200-240 V∼ 200-240 V∼,3A,50/60Hz
8508366.book Page 134 Tuesday, October 23, 2001 11:29 AM