System Error Codes
2-20
HP DesignJets 1050C and 1055CM Printers Service Manual
System Error: 0B0006
Problem
Description:
The Trailing Cable has been incorrectly connected OR the fuse in
the Electronics Module has been burned.
Corrective Action: Turn the Printer OFF and disconnect the trailing cable. Check that
the ends of the Trailing Cable are flat and are not damaged or bent.
Reconnect the Trailing Cable correctly, making sure it is pushed in
firmly (Refer to the instructions on Page 8-39). Power ON the
Printer and check if the Error Code disappears. If the Error Code
continues, replace the Electronics Module (Refer to the instructions
on Page 8-25), making sure you take care when you reconnect the
Trailing Cable.
WARNING PLEASE TAKE CARE WHEN CONNECTING THE
TRAILING CABLE TO THE ELECTRONICS MODULE.
INCORRECT INSTALLATION WILL BURN THE FUSE IN
THE ELECTRONICS MODULE, CAUSING THE COMPLETE
REPLACEMENT OF THE ELECTRONICS MODULE.
System Error: 0B0007
Problem
Description:
Unable to detect Vacuum Fan.
Corrective Action: Try the following:
Make sure that the Vacuum Fan is connected correctly to the
Electronics Module.
Turn the Printer OFF and disconnect the Vacuum Fan from the
Electronics Module. Connect a
New
Vacuum Fan to the
Electronics Module and power ON the Printer. If the
New
Vacuum
Fan functions correctly without any Error Codes then remove the
Old
Vacuum Fan from the Printer and install the
New
one.
If the New Vacuum Fan does not function correctly either, then
replace the Electronics Module Page 8-25.
System Error: 0B0008
Problem
Description:
Unable to detect Cooling Fan.
Corrective Action: Replace the Electronics Module Page 8-25.