HP (Hewlett-Packard) A5799A Network Card User Manual


 
91
the tables and parameters, press Crtl+x to clear the line and enter the
characters for the parameters of choice and press ‘ENTER’.
3. The banner “Press ENTER when ready to receive Configuration
Dump (CTRL+A to Abort)” will appear. Pressing ENTER “DUMPs”
the selected configuration to the screen for viewing.
Procedure for Saving the Configuration Data on the PC
1. Log onto the terminal server as a Master User.
2. Type
DUMP
and press the ENTER key.
The banner
Dump Configuration Details
appears, and a list of
system tables and system parameters displays. View one or more of
the tables and parameters, press Crtl+x to clear the line and enter the
characters for the parameters of choice and press ‘ENTER’.
3.
The banner “Press ENTER when ready to receive Configuration
Dump (CTRL+A to Abort)” will appear.
DO NOT PRESS THE
ENTER KEY. Instead, use the communications program
XModem transfer process to receive the configuration file from
the terminal server. The ‘ENTER’ will be sent by the
communication package and the CONFIG will be saved on the PC
as the filename selected and in the specified directory.
4. To verify that the file was saved correctly, open the file with a text
editor such as “Notepad” or “Wordpad”. The file should appear to
have appropriate programming structure (Look for extraneous
characters) and be terminated with the word “END”.