HP (Hewlett-Packard) A5799A Network Card User Manual


 
125
.DISKCRIT
The RAMDISK has reached a critical level assigned in the Set Disk
Parameters (
SDP
) menu.
Alarm/Event Action Routine Parameters Comments
.DISKCRIT DOLIST
.DISKCRIT-1 PHONHOME
.DISKCRIT-2 SCHEDULE 30 PHONHOME
In the example above, the .DISKCRIT alarm results in the a call to the
default phone number specified in the system parameters. If the alarm is
not canceled, the phone number will be called again in 30 minutes.
.DISKFULL
This alarm is generated when the RAMdisk is full. No additional
information can be stored on the disk. If this occurs, data from host ports
stored in buffer files will be lost.
Alarm/Event Action Routine Parameters Comments
.DISKFULL DOLIST
.DISKFULL-1 PHONHOME
.DISKFULL-2 SCHEDULE 30 PAGE
In this example, the .DISKFULL alarm results in a call to the phone
number set in the System Parameters (
SSP
) menu. If the alarm is not
canceled with 30 minutes, a page is sent to the default pager number.