Reinitializing the Terminal Server
Use a PC or terminal connected to the AUX port to re-initialize the
terminal server. The AUX port must be set at 9600 baud.
Note: This procedure requires that you re-establish your network
parameters and rebuild your user database.
1. Reboot the unit.
2. Watch the LEDs carefully. When the Pulse LED lights, wait
approximately one-half second and press Enter. The following System
LEDs will light: Alarm, Event, and File.
3. Type
INIT
, do not press Enter! You will be asked to confirm system re-
initialization, type
YES
. Begin this step within 10 seconds of
completing step 2.
4. Re-establish your networking parameters (IP and Ethernet, and FTP
addresses).
5. Download the HP.CFG and appropriate configuration files.
6. Configure the terminal server with the HP.CFG file and the
appropriate configuration file. See the next section for further
information about configuration files.
Working with Configuration Files
Each terminal server has a configuration file that specifies the parameters
of the terminal server and determines how the unit operates. This file
includes the Action Table, user Action Routines, System Parameters, and
Parameters of the AUX, Modem, Host Ports and Text Pager Messages.
Configuration files are created online or offline and are saved in ASCII file
format with the extension
*.cfg
. One file can be used to replicate
parameters across multiple terminal servers. Configuration files can be
saved to a storage device, saved to the RAMdisk, or printed to a screen.