HP (Hewlett-Packard) E1366A Computer Hardware User Manual


 
[ROUTe:]
The ROUTe subsystem controls switching and scanning operations for RF
multiplexer modules in a switchbox.
Subsystem Syntax [ROUTe:]
CLOSe <
channel_list>
CLOSe? <
channel_list>
OPEN <
channel_list>
OPEN? <
channel_list>
SCAN <
channel_list>
:MODE NONE | VOLT | RES | FRES
:MODE?
CLOSe [ROUTe:]CLOSe <channel_list> closes the RF multiplexer channels
specified by channel_list. The channel_list has the form (@ccnn) where
cc = card number (01-99) and nn = channel number (00-03 and 10-13).
Parameters
Parameter Name Parameter Type Range of Values
<channel_list>
numeric cc00-cc03, cc10-cc13
Comments Closing Channels: To close:
a single channel, use [ROUTe:]CLOSe (@ccnn)
multiple channels, use [ROUTe:]CLOSe (@ccnn,ccnn)
sequential channels, use [ROUTe:]CLOSe (@ccnn:ccnn)
groups of sequential channels, use
[ROUTe:]CLOSe (@ccnn:ccnn,ccnn:ccnn)
or any combination.
Closure order for multiple channels with a single command is not
guaranteed.
Related Commands: [ROUTe:]OPEN, [ROUTe:]CLOSe?
*RST Condition: All channels open.
Example Closing Multiplexer Channels
This example closes channels 100 and 213 of a two-module switchbox (card
numbers 01 and 02).
CLOS (@100,213) ! Close channels 100 and 213.
100 closes channel 00 of card #1;
213 closes channel 13 of card #2
48 HP E1366A/E1367A RF Multiplexers Command Reference Chapter 5