HP (Hewlett-Packard) LH 6000 Printer User Manual


 
Chapter 4 Diagnostics
54
0B1X Your system has failed to load the Microcode Update data block for the Pentium III microprocessor.
You must correct this problem in order to avoid possible malfunction or reliability problems.
To correct the problem, update your BIOS by running the flash utility from your HP NetServer Navigator CD-
ROM. To do this, insert the HP NetServer Navigator CD-ROM in the CD-ROM drive and power-cycle your
system. See BIOS Recovery.
If updating your BIOS does not clear this error, contact your service representative.
0B2X The Microcode Update data block for the Pentium III microprocessor is defective.
You must correct this problem in order to avoid possible malfunction or reliability problems.
To correct the problem, update your BIOS by running the flash utility from your HP NetServer Navigator CD-
ROM. To do this, insert the HP NetServer Navigator CD-ROM in the CD-ROM drive and power-cycle your
system. See BIOS Recovery.
If updating your BIOS does not clear this error, contact your service representative.
.