Honeywell MAXPRO-NET Switch User Manual


 
Menu is busy The system MENU is already being used by another operator.
Wait a while and try again.
Test mode frozen The diagnostic test mode display has been frozen. The system
MENU cannot be used until the diagnostic test mode is released.
Wait for the service engineer to complete their testing, then try to
access the system MENU again.
LIC:XX_DAYS_LEFT This prompt indicates that you are running a trial version of the
software.
This text is prompted in the message line, if the remaining trial
period is greater than 5 days. If the trial period is less than or equal
to 5 days, then the message is shown in the mode line and the
message is displayed on every monitor once after every thirty
selections.
LIC:EXPIRED This message is displayed on all monitors when the trial period of
software expires. This is displayed on the mode line of every
monitor. No switching is allowed once the license expires and
every issue of the switching command results in a display of this
message.
8.9 ERRORS
Message Prompt Explanation
?? Fault errorlog The ERRORLOG.MAX report file on the storage disk is full. You
should contact technical support as soon as possible to have the
report file analyzed. Once the reported problems have been dealt
with, the service engineer should delete the report file and re-boot
the system.
Runtime error #.. The system has ceased operation completely. Record the Runtime
error number and call technical support for immediate support.
Try re-booting the MAXPRO-Net Server to re-establish normal
system operation.
?? Macro error #.. The internal macro environment in your system has reported an
incomplete macro event. The macro error number can be used to
identify the event problem. Keep written log records of the macro
error number together with the system event causing the macro
error and the time/date it occurred. Macro errors can occur in a
fully functioning system but should be attended to during normal
system maintenance.
Subrack Fail (xxx) The equipment subrack (xxx) in the hardware has failed to respond
to polling commands. The data communication channel to the
subrack may be disconnected or the subrack controller module
may have failed. Call technical support for immediate support.
HL Fail (xxx) The external computer system (xxx) connected to the system has
failed to respond to polling commands. The data communication
channel to this equipment may have failed. Call technical support
for immediate support.
Rev. A 8-9 HMXMU001056