IBM 701X (2630) Laptop User Manual


 
Numeric Error Codes
Numeric error codes show the errors detected in POST or
system operation. Use the error codes displayed on the
screen to diagnose failures. If more than one error code is
displayed, begin the diagnosis with the first error code.
The cause of the first error code can result in false error
codes being displayed.
In the following error codes, X can be any number.
Symptom/Error FRU/Action
02X, 101, 107 1. Battery.
2. AC Adapter
3. Memory Option.
4. Top System Board.
10X 1. Bottom System
Board.
119 1. Top System Board.
161, 163 1. Set Configuration.
(Press Fn+F1 to enter
the Configuration Utility
and set the time and
date.)
2. Top System Board.
3. Bottom System Board.
162
(Check the Installed Devices
list for a missing device.)
1. Set Configuration.
(Press Fn+F1 to enter
the Configuration Utility
and set your
configuration.)
2. Any Missing Device.
3. Top System Board.
4. Bottom System Board.
164
(Memory size error)
1. If a SO-DIMM card
has been removed,
press Fn+F1 to enter
the Configuration
Utility, and verify the
memory size.
2. Replace the installed
SO-DIMM.
3. Bottom System Board.
184 1. Press Fn+F1 to enter
the Configuration
Utility, and then reset
the Power-on
Password.
195
(The hibernate partition
does not match memory
size.)
1. Check if the disk
drive is from another
computer or if the
memory size has
changed.
2. Go to “Hard Disk
Drive Checkout” on
page 133.
3. Hard Disk Drive
142 IBM Mobile Systems HMM