IBM HS40 Server User Manual


 
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
System
under
recommended
voltage
for
+1.5v.
1.
Check
BladeCenter
power
(see
IBM
BladeCenter
Type
8677
Hardware
Maintenance
Manual
and
Troubleshooting
Guide).
2.
Reseat
blade
server.
3.
Replace
blade
server.
System
under
recommended
voltage
for
+2.5v.
1.
Check
BladeCenter
power
(see
IBM
BladeCenter
Type
8677
Hardware
Maintenance
Manual
and
Troubleshooting
Guide).
2.
Reseat
blade
server.
3.
Replace
blade
server.
System
under
recommended
voltage
for
+3.3v.
1.
Check
BladeCenter
power
(see
IBM
BladeCenter
Type
8677
Hardware
Maintenance
Manual
and
Troubleshooting
Guide).
2.
Reseat
blade
server.
3.
Replace
blade
server.
System
under
recommended
5V
fault.
1.
Check
BladeCenter
power
(see
IBM
BladeCenter
Type
8677
Hardware
Maintenance
Manual
and
Troubleshooting
Guide).
2.
Reseat
blade
server.
3.
Replace
blade
server.
System
shutdown
Refer
to
the
following
tables
when
experiencing
system
shutdown
related
to
voltage
or
temperature
problems.
System
errors
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
Internal
Error
CPU
x
fault
1.
Reseat:
a.
I/O
Expansion
Option
b.
Blade
Storage
Expansion
option.
c.
IDE
hard
drive.
2.
Replace:
a.
Failing
PCI
adapter
b.
Microprocessor
x.
c.
I/O
Expansion
Option.
d.
Blade
Storage
Expansion
option.
e.
IDE
hard
drive.
f.
System
board.
100
BladeCenter
HS40
Type
8839:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide