IBM HS40 Server User Manual


 
POST
error
codes
The
following
table
lists
error
codes
that
might
be
sent
to
the
management
module
for
error
logging
as
BMC
pass-through
error
entries
for
the
management
module
system-error
log
(SEL).
Note:
The
syntax
of
error
logging
between
the
management
module
and
the
SEL
might
be
different.
Local
SEL
error
codes
might
differ
from
the
SEL
entries
logged
by
the
management
module
for
identical
event
types.
In
the
following
error
codes,
X
can
be
any
number
or
letter.
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
0000
(Timer
error)
1.
Run
diagnostics.
2.
Battery.
3.
I/O
board.
0005
(CMOS
checksum
bad
loading
defaults)
Information
only;
no
action
required.
0012
(CMOS
date/time
not
set)
Run
the
Configuration/Setup
Utility
program,
and
set
the
date
and
time.
0040
(Refresh
timer
test
failed)
1.
I/O
board
2.
Processor
board
0044
(DMA
controller
error)
I/O
board
0045
(DMA-1
error)
I/O
board
0046
(DMA-2
error)
I/O
board
004C
(Keyboard/interface
error)
I/O
board
004D
(Primary
master
hard
disk
error)
1.
Reset
primary
hard
disk.
2.
Run
diagnostics.
3.
Primary
hard
disk.
4.
I/O
board.
004F
(Secondary
master
hard
disk
error)
1.
Reset
secondary
hard
disk.
2.
Run
diagnostics.
3.
Secondary
hard
disk.
4.
I/O
board.
0055
(Primary
master
drive
-
ATAPI
incompatible)
Primary
master
hard
disk
drive
0057
(Secondary
master
drive
-
ATAPI
incompatible)
Secondary
master
hard
disk
drive
005D
(ATA
SMART
failure
error
(dynamic
string))
ATA
drive
Chapter
6.
Symptom-to-FRU
index
79