IBM HS40 Server User Manual


 
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Number
of
beeps/symptom
FRU/action
5
short,
1
long
(No
memory
found
in
system)
1.
Install
or
reseat
memory,
then
perform
a
blade
server
reset.
2.
DIMMs.
3.
Processor
board.
6
short,
1
long
(Memory
is
not
DDR
type)
1.
Replace
with
supported
DIMMs.
2.
DIMMs.
3.
Processor
board.
7
short,
1
long
(SMBUS
error.
Memory
enumerations
cannot
proceed.)
1.
Processor
board
2.
I/O
board
Baseboard
management
controller
(BMC)
beep
codes
The
following
table
lists
the
BMC
error
beep
codes.
Beep
code/symptom
FRU/action
1-5-1-1
(Microprocessor
failure)
1.
Microprocessor
2.
Processor
board
1-5-2-2
(No
microprocessors)
1.
Microprocessor
2.
Processor
board
1-5-2-3
(VID
mismatch,
population
rules
violation,
microprocessor
mismatch)
1.
Make
sure
all
microprocessors
are
supported
by
the
BIOS
and
of
the
same
family,
model,
stepping,
speed,
and
cache
size.
2.
Microprocessor.
1-5-4-2
(Power
fault:
dc
power
unexpectedly
lost)
1.
Reseat
blade
server
and
power
cycle
the
blade
server.
2.
Reseat
dc
power
cable.
3.
Processor
board.
4.
I/O
board.
1-5-4-4
(Power
control
fault)
1.
Reseat
blade
server
and
power
cycle
the
blade
server.
2.
Flex
cable.
3.
Auxiliary
power
cable.
4.
Processor
board.
5.
I/O
board.
No-beep
symptoms
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
No-beep
symptom
FRU/action
No
beep
and
no
video
(System
error
LED
is
OFF)
See
“Undetermined
problems”
on
page
101.
No
beep
and
no
video
(System
Attention
LED
is
ON)
See
“Diagnosing
problems
using
the
light
path
diagnostics
feature”
on
page
27.
78
BladeCenter
HS40
Type
8839:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide