Status byte 5, bit 0 is set to 1 when responding to the extended address
command. (See Status Summaryon page 160.)
where:
Byte 1
Device type = 30
Byte 2
Device ID.
00 Models TI1 and TI2 (impact DI/thermal CR)
01 Models TI3 and TI4
02 Models TI5 and TG5, or Models TI3 and TI4 with 2-MB
option
03 Models TM6 and TF6 (512K; thermal CR)
04 Models TI3 and TI4 with the 8-MB option
05 Models TM6 and TF6 with the 8-MB option
06 Reserved
07 Models TF7 and TM7
Byte 3
Features.
Bit 0 Set to 1 when MICR is present
Bit 1 Set to 1 when check flipper is present
Bit 2 Set to 1 when byte 2 is set to 02
Bit 3 Set to 1 when printer is in XON/XOFF mode
Bit 4 Set to 1 when printer is in DBCS mode
Bit 5 Set to 1 when the 2-MB option is used for user flash
memory, instead of being used for DBCS storage
Bit 6 Set to 1 when the printer has capability of printing two
colors.
Bit 7 Set to 1 when the printer is in Model 4 emulation mode.
Byte 4
Second byte of features
Bit 0 Set to 1 when printer is setup for 58-mm paper. (Only valid
for models TF7 and TM7.)
Byte 5
EC level = EC level of loaded code
Error Conditions:
None.
Remarks: