Intelligent Motion Systems 17 Network Card User Manual


 
34
H
Delays program execution in milliseconds.
Switches to program mode at address 200 PG 200
Label command will name the program LB K1
xxxxx
Program named by LB command xxxxx
xxxxx
Delay 2 seconds between re-execution of program H 2000
Unconditional branch to K1 BR K1
Designates the end of the program E
Switches out of program mode P
PRINT
Outputs specified text and parameter values to a terminal or terminal software on a Host PC.
Switches to program mode at address 200 PG 200
Label command will name the program LB K1
xxxxx
Program named by LB command xxxxx
xxxxx
Prints text in quotes and then POS PR “Position = ” P
Delay 2 seconds between re-execution of program H 2000
Unconditional branch to K1 BR K1
Designates the end of the program E
Switches out of program mode PG
VAR
Command used to define a variable with 8 alphanumeric characters.
Switches to program mode at address 200 PGM 200
Define a variable named CT for Count VAR CT
Label command will name the program LBL K1
xxxxx
Program named by LB command xxxxx
xxxxx
Prints text in quotes and then POS PRINT “Position = ” P
Delay 2 seconds between re-execution of program H 2000
Unconditional branch to K1 BR K1
Designates the end of the program E
Switches out of program mode PGM