Table 6-13. SVID Signals
SVIDALERT_N Serial VID alert.
SVIDCLK Serial VID clock.
SVIDDATA Serial VID data out.
Table 6-14. Processor Asynchronous Sideband Signals (Sheet 1 of 3)
Signal Name Description
BIST_ENABLE
BIST Enable Strap. Input which allows the platform to enable or
disable built-in self test (BIST) on the processor. This signal is
pulled up on the die, refer to Table 7-6 for details.
BMCINIT
BMC Initialization Strap. Indicates whether Service Processor Boot
Mode should be used. Used in combination with FRMAGENT and
SOCKET_ID inputs.
0: Service Processor Boot Mode Disabled. Example boot
modes: Local PCH (this processor hosts a legacy PCH with
firmware behind it), Intel QPI Link Boot (for processors one
hop away from the FW agent), or Intel QPI Link Init (for
processors more than one hop away from the firmware agent).
1: Service Processor Boot Mode Enabled. In this mode of
operation, the processor performs the absolute minimum
internal configuration and then waits for the Service Processor
to complete its initialization. The socket boots after receiving a
“GO” handshake signal via a firmware scratchpad register.
This signal is pulled down on the die, refer to Table 7-6 for details.
CAT_ERR_N
Indicates that the system has experienced a fatal or catastrophic
error and cannot continue to operate. The processor will assert
CAT_ERR_N for nonrecoverable machine check errors and other
internal unrecoverable errors. It is expected that every processor
in the system will wire-OR CAT_ERR_N for all processors. Since
this is an I/O land, external agents are allowed to assert this land
which will cause the processor to take a machine check exception.
This signal is sampled after PWRGOOD assertion.
On the processor, CAT_ERR_N is used for signaling the following
types of errors:
Legacy MCERR’s, CAT_ERR_N is asserted for 16 BCLKs.
Legacy IERR’s, CAT_ERR_N remains asserted until warm or
cold reset.
CPU_ONLY_RESET Reserved, not used.
ERROR_N[2:0]
Error status signals for integrated I/O (IIO) unit:
0 = Hardware correctable error (no operating system or
firmware action necessary)
1 = Non-fatal error (operating system or firmware action
required to contain and recover)
2 = Fatal error (system reset likely required to recover)
FRMAGENT
Bootable Firmware Agent Strap. This input configuration strap
used in combination with SOCKET_ID to determine whether the
socket is a legacy socket, bootable firmware agent is present, and
DMI links are used in PCIe* mode (instead of DMI2 mode).
The firmware flash ROM is located behind the local PCH attached to
the processor via the DMI2 interface.This signal is pulled down on
the die, refer to Table 7-6 for details.