DataSafe NAS User’s Manual 149
4. Click the checkbox next to each alert level for
which you want email messages sent.
5. In the To: field, specify the email address of the
person who should respond to the alert
(administrator). Address should be entered in the
form administratorname@domainname.com.
6. Leave the With field blank if email should be sent
directly to the specified address. If email should
be sent through an SMTP gateway, enter the name
or IP address.
7. Click the Test button to send a sample email
message to the administrator, specifying the
server name and confirming correct configuration
of Alert Email.
Alert messages to administrators contain a link to
the URL of the error message.
LED Alerts
During boot-up and power-down the soft power LED
blinks and beeps. During operation, the LED can have
one of four possible states: steady off, steady on, fast
blinking and slow blinking. In the fast blinking state,
the flashing period is 300msec with 50% duty cycle. In
the slow blinking state, the flashing period is
600msec with 50% duty cycle. The count is equivalent
to the LED being off the full number of cycles
indicated. To indicate the blinking is beginning, there
is a short pause when the LED is off. The length is half
the flashing period. To see the message for different
descriptions with the same LED blink code, see web
UI. Click the “Status” indicator at top to get a list of
messages. Click a specific message to see details.