Kodak A-41069 Scanner User Manual


 
7 - 2
A-41069 January 1993
Trouble
Clear streak on scanned
images.
Overall scanned image density
too light, too dark, or uneven.
Calibration failure.
Probable Cause Remedy
Foreign object in the optical path. Refer to Section 8.
Check and clean imaging
guides and transport area.
Dust or dirt on mirrors or imaging Refer to Section 8.
Check and
guides. clean imaging guides and
mirrors.
Calibration not performed or not Refer to Section 3. Perform
performed correctly. calibration using instructions
provided.
Lamps are dirty or not properly Refer to Section 8. Check the
installed. lamps for proper installation.
Check for dirt or debris in the
lamp housing.
Calibration target skewed when Retry. Adjust feed tray
feeding. side guides. Adjust
feed and
separator roller gap.
Lamps are dirty or not properly Refer to Section 8. Check the
installed. lamps for proper installation.
Check for dirt or debris in the
lamp housing.
Document in the transport at the Refer to Section 7.
Remove
time of calibration. any documents in the transport
system. Retry.