Lantronix 900-598 Network Hardware User Manual


 
12: Advanced Settings
PremierWave XC User Guide 89
Failover Settings Description
Ping Timeout Interval
Enter the value for the Ping Timeout Interval.
Maximum duration of executing one Ping command.
Note: Default value is 30.
Ping Interval
Enter the value for the Ping Interval.
Device will ping Remote host every defined seconds.
Note: Default value is 3.
Max. Failed Pings
(before Failover)
Enter the number for Max. Failed Pings
If device fails to connect after defined attempts, device will failover to
secondary connection.
Note: Default value is 5.
Consecutive Successful
Pings (before fallback)
Enter the number for Consecutive Successful Pings
After default connection is up, device will revert to default connection after
defined continuous successful pings.
Note: Default value is 5.
Ethernet Host Address
Specify the Ethernet Host address.
Define the Ethernet host address to ping when using Ethernet as default
connection.
Wwan0 Host Address
Specify the Wwan0 Host address.
Define the Wwan0 host address to ping when using Wwan0 as default
connection.
To Configure Failover Settings
Using Web Manager
To configure failover settings, click Fail Over on the menu bar.
Using the CLI
To enter the XML command level: enable -> config → failover mode
Using XML
Include in your file: <configgroup name=”failover mode”>