Lantronix 900-691-R Network Card User Manual


 
5: Interface Settings
xPico® Wi-Fi® Embedded Device Server User Guide 31
To Configure Line Settings
Note: The following section describes the steps to view and configure Line 1 settings;
these steps apply to other line instances of the device.
Using Web Manager
To configure a specific line, click Line in the menu and select Line 1 -> Configuration
(Table 5-1).
Using CLI
To enter the Line command level: config -> Line <instance>
Using XML
Include in your file: <configgroup name = "Line" instance = "1">
To View Line Status
Using Web Manager
To view statistics for a specific line, click Line in the menu and select Line 1 -> Status.
Using CLI
To enter the Line command level: status -> Line <instance>
Using XML
Look for the status header: <statusgroup name = "Line" instance = "1">
Xoff Char Specify the Xoff Character which is used when Flow Control is set to
Software. Set the prefix in one of the three ways:
Prefix decimal with prefix hexadecimal and 0x
Prefix hexadecimal with 0x
Prefix as a single control character with <control>
Gap Timer Set the Gap Timer delay to Set the number of milliseconds to pass from the
last character received before the driver forwards the received serial bytes.
By default, the delay is four character periods at the current baud rate
(minimum 1 msec). Gap Timer range is 1 to 5000 milliseconds.
Threshold Set the number of threshold bytes which need to be received in order for the
driver to forward received characters. Default value is 56 bytes.
Line Settings Description