Lantronix 900-691-R Network Card User Manual


 
Appendix A: Command Reference
xPico® Wi-Fi® Embedded Device Server User Guide 88
configitem Incoming Connection
value
Incoming Connection requests may be disabled (ATS0=0), answered automatically (ATS0=1), or
answered manually via the ATA command after an incoming RING (ATS0=2 or higher).
Incoming Connection may be "Disabled", "Automatic" or "Manual".
configitem Connect String
value
The Connect String is a customized string that is sent to the Serial Line with the CONNECT Modem
Response Code.
Connect String may contain up to 30 characters.
configitem Display Remote IP
value
With Display Remote IP enabled, the incoming RING sent on the Serial Line is followed by the IP
address of the caller.
Display Remote IP may be "Enabled" or "Disabled".
configgroup Monitor Initialization
These settings pertain to Monitor Initialization in the device.
Monitor will process any initialization message before it starts polling or process any control message.
Response captured during initialization will be overwritten by any poll or control response.
configitem Initial Delay
value
Sets Initial Delay waited before monitor start processing any initialization message.
Initial Delay has units of milliseconds.
configitem Message
value Command
Sets the Command in binary format.
Binary format takes printable characters (e.g. 'abc' for characters 'a', 'b' and 'c') or binary string (e.g. [0xa,
0xd] for line feed and carriage return).
Command may contain up to 16 bytes.
value End Character
Sets the End Character to indicate end of response.
Response is ended by any configured End Character, Length OR Timeout.
The End Character may be designated as a single printable character or as a control character.
Control characters may be input in any of the following forms:
<control>J
0xA (hexadecimal)