Lantronix 900-691-R Network Card User Manual


 
Appendix A: Command Reference
xPico® Wi-Fi® Embedded Device Server User Guide 81
configitem Name
value
The Name is for display purposes only.
Name may contain up to 25 characters.
configitem State
value
Enable the State to allow the Serial Line to operate.
State may be "Enabled" or "Disabled".
configitem Protocol
value
Protocol selects the application to connect to the Line:
None selects no application to connect to the Line.
Tunnel sets up the Line to work with the Tunnel application. See the Tunnel configuration options for
details.
Trouble Log sets up an output-only message log on the device. Severity codes in the log are:
P Emergency
A Alert
C Critical
E Error
W Warning
N Notice
I Informational
D Debug
Command Line sets up a user interface containing commands to show device status and to change
configuration. Simply paste in XML configuration to apply its settings to the device.
Protocol may be "Command Line", "Modem Emulation", "Monitor", "None", "Trouble Log" or "Tunnel".
configitem Baud Rate
value
When specifying a Custom baud rate in the Web Manager, select '
Custom' from the drop down list and
then enter the desired rate in the text box.
Baud Rate has units of bits per second.
configitem Parity
value
Parity may be "None", "Even" or "Odd".
configitem Data Bits
value
Data Bits may be "7" or "8".