Lenovo 24684XU Laptop User Manual


 
Message: 0187: EAIA data access error
Solution: Check Security settings. Press F10 and then press Enter to restart the system.
Message: 0188: Invalid RFID Serialization Information Area
Solution: Reset the Block # 0 and 1, for example, the box serial number, and/or the Block # 4 and 5,
for example, the UUID. It could be done by using maintenance diskette or USB key. If you still have a
problem, have the computer serviced.
Message: 0189: Invalid RFID conguration information area
Solution: The EEPROM checksum is not correct (block # 4 and 5). See Solution for 0188.
Message: 0190: Critical low-battery error
Solution: The computer turned off, because the battery is low. Connect the ac power adapter to the
computer and charge the battery, or replace the battery with a fully charged one.
Message: 0191: System Security - Invalid remote change requested
Solution: Bad system conguration change request has been detected, the BootBlock update has failed,
or unknown request packet has been detected. To clear the error, enter ThinkPad Setup.
Message: 0199: System Security - Security password retry count exceeded.
Solution: This message is displayed if you enter a wrong supervisor password more than three times.
Conrm the supervisor password and try again. To clear the error, enter ThinkPad Setup.
Message: 0251: System CMOS checksum bad - Default conguration used
Solution: The system CMOS might have been corrupted or modied incorrectly by a program that
changes data stored in CMOS. The computer uses the default settings. Run ThinkPad Setup to recongure
the settings. If you still see the same error code, check the system battery or have the computer serviced.
Message: 0271: Real Time Clock error - Check Date and Time settings.
Solution: Neither the date nor the time is set in the computer. Set the date and time through ThinkPad
Setup.
Message: 1802: Unauthorized network card is plugged in - Power off and remove the network card.
Solution: The Mini PCI Express network card is not supported on this computer. Remove it.
Message: 2000: ThinkVantage Active Protection sensor diagnostics failed.
Solution: ThinkVantage Active Protection sensor is not working correctly. Have the computer serviced.
Message: 2100: Detection error on HDD0(Main HDD)
Solution: The hard disk is not working. Have the hard disk serviced.
Message: 2102: Detection error on HDD2(Mini SATA)
Solution: The Mini SATA device is not working. Have the Mini SATA device serviced.
Message: 2110: Read error on HDD0(Main HDD)
Solution: The hard disk is not working. Have the hard disk serviced.
Message: 2112: Read error on HDD2(Mini SATA)
Solution: The Mini SATA device is not working. Have the Mini SATA device serviced.
Message: 2200: Machine Type and Serial Number are invalid.
Solution: POST warning message in case MTMSN is not set correctly. Have the computer serviced.
Message: 2201: Machine UUID is invalid.
Solution: POST warning message in UUID is not set correctly. Have the computer serviced.
Message: Fan error
Solution: Cooling fan has failed. Have the computer serviced.
Message: Thermal sensing error.
Chapter 10. Troubleshooting computer problems 133