10. Advanced functions
10-12 SV-iC5
Factory default of motor parameters (Function group 2)
H30-Motor
rating
[kW]
H32-Rated slip
freq
[Hz]
H33-Current
rating
[A]
H34-No-load
current
[A]
H42-Stator
resistance []
H44-Leakage
inductance
[mH]
0.2 0.9 0.5 3.0 14.0 122.0
0.4 1.8 1.1 3.0 6.7 61.58.893
0.75 3.5 2.1 2.33 2.46 28.14
1.5 6.5 3.5 2.33 1.13 14.75
2.2 8.8 4.4 2.0 0.869 11.31
10.10 Energy-saving operation
Group LED Display Parameter Name
Set
value
Min/Max
Range
Factory
Defaults
Unit
Function
group 1
F40 [Energy-saving level] -
0/30 0 %
Set the amount of output voltage to be reduced in F40.
Set as the percent of Max output voltage.
For fan or pump applications, energy consumption can be dramatically reduced by decreasing the output
voltage when light or no load is connected.
10.11 Speed Search
Group LED Display Parameter Name
Set
value
Min/Max
Range
Factory
Defaults
Unit
H22 [Speed Search Select] -
0/15 0
H23
[Current level during Speed
search]
- 80/200 100 %
H24 [P gain during Speed search] - 100
Function
group 2
H25 [I gain during speed search] -
0/9999
1000
I54
[Multi-function output
terminal select]
15 12
I/O group
I55 [Multi-function relay select] 15
0/20
17
This is used to prevent possible fault from occurring if the inverter outputs the output voltage during operation
after the load is removed.
The inverter estimates the motor rpm based on output current, so detecting exact speed is difficult.