LG Electronics SV-iC5 Series Power Supply User Manual


 
10. Advanced functions
10-17 SV-iC5
Used when an inverter operates 2 motors connected to two different types of the loads.
2
nd
motor operation does not run 2 motors at the same time. As the figure below, when using
two motors with an inverter by exchanging them, different values can be set for the 2
nd
motor via the
Multi-function input terminal and parameters set in H81-H90.
Turn the I24(setting: 12) On after motor is stopped.
Parameters from H81 to H90 are applied to the 1
st
motor as well as the 2
nd
motor.
10.14 Parameter initialize & Lock
Parameter initialize
Group LED Display Parameter Name
Min/Max
Range
Factory
Default
H93 [Parameter initialize] 0
- 0
1
Initialize all 4 parameter
groups
2
Initialize Drive group Only
3
Initialize Function group 1
Only
4
Initialize Function group 2
Only
Function
group 2
5
Initialize I/O group Only
Select the group to be initialized and initialize the parameters in H93.
Press the Prog/Ent (z) key after selecting the desired number in H93. H93 will reappear after the
setting.