LG Electronics SV-iC5 Series Power Supply User Manual


 
7. Function list
7-17 SV-iC5
I/O group
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
I13 [Frequency
corresponding
to I 12]
0/400
[Hz]
Set the inverter output minimum frequency at
minimum current of I input.
0.0 O
I14 [I input max
current]
0/20
[mA]
Set the Maximum Current of I input. 20 O
I15 [Frequency
corresponding
to I 14]
0/400
[Hz]
Set the inverter output maximum frequency at
maximum current of I input.
60.0 O
0 Disabled
1 Less than half the value set in I 2/7/12
entered
I16 [Criteria for
Analog Input
Signal loss]
0/2
2 Below the value set in I 2/7/12 entered
0 O 12-7
0 Forward run command {FX} I20 [Multi-function
input terminal
P1 define]
1 Reverse run command {RX}
0 O 9-7
2 Emergency Stop Trip {EST} I21 [Multi-function
input terminal
P2 define]
3 Reset when a fault occurs {RST}.
1 O
4 Jog operation command {JOG} 10-3I22 [Multi-function
input terminal
P3 define]
5 Multi-Step frequency – Low
2 O
6 Multi-Step frequency – Mid I23 [Multi-function
input terminal
P4 define]
7 Multi-Step frequency – High
3 O
9-6
8 Multi Accel/Decel – Low
9 Multi Accel/Decel – Mid
10 Multi Accel/Decel – High
9-12
11 DC brake during stop 10-2
12 2
nd
motor select 10-
16
13 -
14 -
I24 [Multi-function
input terminal
P5 define]
0/24
15 Up-down
operation
Frequency
increase
command (UP)
4 O
10-4