LG Electronics SV-iC5 Series Power Supply User Manual


 
7. Function list
7-10 SV-iC5
Function group 2
LED
display
Parameter
name
Min/Max
range
Description
Factory
defaults
Adjustable
during run
Page
This parameter is active to prevent any
possible fault when the inverter outputs its
voltage to the running motor.
1. H20-
[Power
On start]
2.Restart
after
instant
power
failure
3.Operation
after fault
occurred
4.Normal
acceler-
ation
Bit 3 Bit 2 Bit 1 Bit 0
0 - - - -
1 - - -
3
2 - -
3
3 - -
3 3
4 -
3
- -
5 -
3
-
3
6 -
3 3
7 -
3 3 3
8
3
- - -
9
3
- -
3
10
3
-
3
-
11
3
-
3 3
12
3 3
- -
13
3 3
-
3
14
3 3 3
-
H22
2)
[Speed
Search Select]
0/15
15
3 3 3 3
0 O 10-
12
H23 [Current level
during Speed
search]
80/200
[%]
This parameter limits the amount of current
during speed search.
The set value is the percentage of the H33-
[Motor rated current].
100 O
H24 [P gain during
Speed search]
0/9999 It is the Proportional gain used for Speed
Search PI controller.
100 O
H25 [I gain during
speed search]
0/9999 It is the Integral gain used for Speed search
PI controller.
1000 O
10-
12
2) #4.Normal acceleration has first priority. Even though #4 is selected along with other bits, Inverter starts Speed search #4.